◎ Global Shippingϟ Fast RFQ Response◇ Multi-Brand Supply
Request a Quote
Eaton Bussmann

Eaton Bussmann 90CIL14 90A 600V AC HRCI Misc. Type K Fuse

Part Number: 90CIL14

● Check availability

90CIL14: 90A; 600V AC; HRCI Misc. Type K; Overload + Short-Circuit; 200kA AC.

Rated Current90A
Rated Voltage600V AC
Breaking Capacity200kA AC

Eaton Bussmann 90CIL14 is a hrci misc. type k fuse rated 90A at 600V AC. Interrupting/withstand rating: 200kA AC. Typical applications: Motor circuits, Transformers, Inductive loads. Source: Bussmann Full Line Catalog 1007 (2018), page 5-5.

Quick answer, specifications & FAQ
Direct answer

Eaton Bussmann HRCI Fuse 90CIL14 is rated 90A, 600V AC, Overload + Short-Circuit. Breaking capacity 200kA AC, certifications CSA Certified|CE. Listed applications: Inductive loads, Motor protection, Transformer protection. Standards: CSA Class 1422-02. 90CIL14: 90A; 600V AC; HRCI Misc. Type K; Overload + Short-Circuit; 200kA AC.

Last updated 39 days ago

Key specifications

  • Part number: 90CIL14
  • Brand: Eaton Bussmann
  • Rated current: 90A
  • Rated voltage: 600V AC
  • Breaking capacity: 200kA AC
  • Fuse speed: Overload + Short-Circuit
  • Terminal type: Offset Blade
  • Certifications: CSA Certified|CE
  • Standards: CSA Class 1422-02
  • Typical lead time: 12-16 weeks
  • Source: Bussmann Full Line Catalog 1007 (2018), page 5-5.

Frequently asked questions

What are the current and voltage ratings of 90CIL14?

90CIL14 is rated 90A at 600V AC.

What is the breaking capacity of 90CIL14?

90CIL14 has a breaking capacity of 200kA AC. Confirm this covers the available fault current at the installation point.

Which standards and approvals apply to 90CIL14?

90CIL14 is listed under CSA Class 1422-02 / CSA Certified|CE.

What is 90CIL14 used for?

90CIL14 is listed for Inductive loads, Motor protection, Transformer protection applications. Verify suitability for your circuit before ordering.

What are the ordering terms for 90CIL14?

90CIL14: typical lead time 12-16 weeks. Submit a quote request for a firm quotation.

Data sources

Part number
90CIL14
Brand
Eaton Bussmann
Last updated
2026-09-24
Canonical URL
https://fusestock.com/products/eaton-bussmann-90cil14/

Technical Specifications

Part Number
90CIL14
Manufacturer Part Number
90CIL14
Series
CIL Series (HRCI Misc. Type K)
Fuse Type
HRCI Fuse
Current Rating
90A
Voltage Rating
600V AC
AC / DC
AC
Breaking Capacity
200kA AC
Mounting
Bolt Mount
Application
Inductive loads · Motor protection · Transformer protection
Standard
CSA Class 1422-02
Terminal Type
Offset Blade
Fuse Speed
Overload + Short-Circuit
Utilization Class
HRCI Misc. Type K
Approvals
CE · CSA Approval (Unspecified)
Certifications
CSA Certified|CE
Reference Lead Time
12-16 weeks
Source
Bussmann Full Line Catalog 1007 (2018), page 5-5.