Type / Class Image Voltage Rating Current Range Breaking Capacity Typical Applications
Class CC
UL 248-4 · Rejection-type, current-limiting
Class CC fuse - Eaton Bussmann series
600 V AC
300 V DC
0.1 – 60 A
200 kA
Very high · AC
Control transformers, small motors, lighting branch circuits, panelboard feeders.
Class CF (CUBEFuse)
UL Class CF · Finger-safe, UL 98 disconnect rated
TCFCUBEFuseBMM holder
Class CF (CUBEFuse) fuse - Eaton Bussmann series
600 V AC
300 V DC
1 – 400 A
300 kA
≤ 100 A · 200 kA above
IP20 finger-safe panels, compact OEM enclosures, motor disconnects.
Class J
UL 248-8 · Time-delay & fast-acting
Class J fuse - Eaton Bussmann series
600 V AC
300 V DC
1 – 600 A
200 – 300 kA
Very high · current-limiting
Motor branch circuits, VFD input, transformer primary, general distribution.
Class L
UL 248-10 · Main & feeder protection
Class L fuse - Eaton Bussmann series
600 V AC
300 V DC
601 – 6 000 A
300 kA
Very high · AC
Service entrance, main switchboards, large feeders, high-rise risers.
Class RK1
UL 248-12 · Dual-element, time-delay
Class RK1 fuse - Eaton Bussmann series
250 / 600 V AC
125 – 300 V DC
0.1 – 600 A
200 – 300 kA
Very high · current-limiting
Motor circuits, combination starters, retrofit into Class H / RK5 holders.
Class RK5
UL 248-12 · Dual-element, time-delay
Class RK5 fuse - Eaton Bussmann series
250 / 600 V AC
125 – 300 V DC
0.1 – 600 A
200 kA
High · AC
Cost-sensitive motor & transformer protection, legacy panel upgrades.
Class T
UL 248-15 · Fast-acting, compact body
Class T fuse - Eaton Bussmann series
300 / 600 V AC
JJN 160 V DC · JJS none
1 – 1 200 A
200 kA
High · AC
Space-limited panels, lighting, disconnects, busway taps.
Class H / K
UL 248-6 / -9 · One-time & renewable
NONNOSRENRES
Class H / K fuse - Eaton Bussmann series
250 / 600 V AC
Non-current-limiting
1 – 600 A
10 – 50 kA
Low · H 10 kA / K 50 kA
Legacy equipment replacement, general-purpose non-current-limiting duty.
NH (DIN) / BESS
IEC 60269 · gG / gPV / aR blade links
NH1 · NH2 · NH3BESS links
NH (DIN) / BESS fuse - Eaton Bussmann series
690 V AC
1 000 V DC
40 – 1 250 A
120 kA
Very high · IEC
Battery energy storage clusters, LV distribution, industrial main boards.
High-Speed Semiconductor
IEC 60269-4 · aR / gR, UL recognized
High-Speed Semiconductor fuse - Eaton Bussmann series
250 – 1 500 V
AC / DC, series dependent
10 – 2 000 A
200 kA
Very high · extremely low I²t
VFDs, UPS, rectifiers, traction converters, electrolyzers.
Solar PV (gPV)
UL 2579 / IEC 60269-6 · 1 000 – 1 500 V DC
CHPVXL seriesPV-A2
Solar PV (gPV) fuse - Eaton Bussmann series
1 000 – 1 500 V DC
gPV characteristic
1 – 600 A
50 kA
DC rated · per UL 2579
String protection, combiner boxes, inverter input, array isolation.
EV / Battery Pack
Automotive & DC fast-charge · aR / EV fuse
EVKEVHEVREV1845EV20 / EV30
EV / Battery Pack fuse - Eaton Bussmann series
500 – 1 000 V DC
Traction & charger circuits
50 – 500 A
20 – 50 kA
DC rated · high cyclic life
Traction battery packs, BDU / PDU, on-board chargers, DC charging piles.

Notes|Breaking capacity = interrupting rating (IR) at rated voltage; AC and DC ratings differ and are shown separately where applicable.
|Voltage and current ranges are the envelope across the listed series — individual catalogue numbers may cover a narrower band.
|All figures are UL / CSA (or IEC where noted) maximum ratings; always confirm against the dedicated series datasheet before specifying.