Twenty-five Bussmann series across three application blocks: traction & on-board protection, DC fast-charge circuits, and battery energy storage — 70 V DC auxiliary up to 2 000 V DC clusters.
EV Charging
Energy Storage
| Series | Image | Voltage Rating | Current Range | Breaking Capacity | Typical Applications |
|---|---|---|---|---|---|
|
EVK
Bolt-on · aR (EV) · UL 248-20 / ISO 8820-8 / JASO D622
|
![]() |
1 000 V DC
Main HV platform
|
15 – 600 A
|
25 kA
High · DC, TC 2 ms
|
Main battery pack, BDU / junction box, high-voltage DC bus, e-axle feed. |
|
EBPS
Pyro switch · active triggering < 2 ms · dual / single trigger
|
![]() |
1 000 V DC
400 A body
|
400 A
|
16 kA
@ 500 V DC · active < 2 ms
|
Battery pack main disconnect, crash and fault-triggered isolation, MSD replacement. |
|
EVKR
Bolt-on · EV class · ISO 8820-8 / JASO D622
|
![]() |
800 – 1 000 V DC
Series dependent
|
20 – 400 A
|
20 – 25 kA
High · DC
|
Pack-level protection, DC fast-charge inlet, compact modules and sub-packs. |
|
EVPR
10 mm body · auxiliary & on-board charger · GB/T 31465
EVPR10-30EVPR10-40EVPR10-50
|
![]() |
850 V DC
Higher-voltage auxiliary
|
30 – 50 A
|
20 kA
Moderate · TC 2 ms
|
On-board charger, PTC heater, DC-DC auxiliary branch on 800 V platforms. |
|
EVR
Bolt-on · EV class · ISO 8820-8 / GB/T 31465
|
![]() |
500 V DC
400 / 500 V platforms
|
30 – 1 000 A
|
20 – 50 kA
High · DC, up to 50 kA ≥ 350 A
|
400/500 V platforms, DC-DC converter, auxiliary drives, older EV designs. |
|
EV
Full range · 10 – 63.5 mm bodies · JASO D622 / ISO 8820-8
|
![]() |
500 V DC
Full-range characteristic
|
5 – 1 000 A
|
20 – 50 kA
min 135–200% · 50 kA ≥ 350 A
|
EV10 auxiliary (5–50 A); EV20 – EV60 main pack, BDU and e-axle (50–1 000 A). |
|
XEV
aR · JASO D622 / ISO 8820-8 · serialised for traceability
XEV10XEV30XEV1XSQ
|
![]() |
500 V DC
50 – 400 A bodies
|
50 – 400 A
|
20 kA
Moderate · DC
|
Battery management system, on-board charger, charging inlet protection. |
|
EVH
Bolt-on · low-voltage auxiliary · TC 2 ± 0.5 ms
|
![]() |
70 V DC
12 / 24 / 48 V systems
|
60 – 500 A
|
6 kA
Moderate · aux only
|
12/24/48 V auxiliary circuits, heavy-gauge cable and busbar protection. |
|
FWJ
Stud-mount · North American style · CE / UL 35–600 A
|
![]() |
1 000 V AC
800 V DC · 450 – 600 A
|
35 – 2 000 A
|
25 – 100 kA
High · 50 kA @ 800 V DC
|
Rectifier and PFC stage, DC bus inside charger power modules, high-current stacks. |
|
FWE
Ultra-rapid · IEC 60269-4 / UL 248-13 · designed for EV chargers
FWE-15AFWE-60AFWE-200AFWE-600A
|
![]() |
1 000 V DC
10×38 / 14×51 / round body
|
15 – 600 A
|
50 kA
Very high · TC 10 ms
|
DC conditioning circuits, high-voltage DC/DC converters, charger output up to 400 kW+. |
|
CBX01S
aR · UL 248 · 1 000 V charger platform
|
![]() |
1 000 V DC
DC output side
|
32 – 400 A
|
50 kA
Very high · DC
|
DC fast-charge power modules, charger output, gun-side short-circuit protection. |
|
CBX000S
aR · Size 000 body · IEC 60269 · 800 V platform
|
![]() |
800 V DC
IEC rating
|
25 – 400 A
|
50 kA
Very high · TC 10 ms
|
800 V charging platforms, compact 000-size cabinets, retrofit into tight enclosures. |
|
EVP10
EV class · 750 V platform · small-frame
EVP10-15AEVP10-30AEVP10-60A
|
![]() |
750 V DC
Control / auxiliary
|
15 – 60 A
|
20 kA
Moderate · DC
|
Auxiliary power supply and control circuits inside the charger cabinet. |
|
FWP-C
Stud-mount · 700 V · CCC + UL · AC and DC rated
FWP-35CFWP-200CFWP-400CFWP-600C
|
![]() |
700 V AC / DC
Dual rated
|
35 – 600 A
|
200 kA AC
50 kA DC · very high
|
Rectifier and DC bus protection in charger power stages, AC input side. |
|
FWH-C
Bolted tags · ESS Solution 500 V DC series · CCC + UL
|
![]() |
500 V DC
ESS Solution series
|
35 – 800 A
|
50 kA DC
200 kA AC · CCC + UL
|
DC common bus and power converters / rectifiers in charger power stages. |
|
ESS20HB
aBat · IEC 60269-7 · 2 000 V cluster class
|
![]() |
2 000 V DC
Highest voltage class
|
450 / 630 A
|
150 kA
Very high · TC ≤ 3 ms
|
2 000 V high-voltage battery clusters, PCS DC side, next-gen container designs. |
|
CBMG
Bolted · 1 500 V DC · ultra-high current cluster main
|
![]() |
1 500 V DC
Max operating voltage
|
1 250 – 4 000 A
|
300 kA
10 ms L/R · 250 kA @3–4 ms
|
Megawatt-scale BESS cluster main, container disconnect, DC busbar tie. |
|
ESS5
aR · IEC 60269-4 / UL 248-13 · 1 500 V
|
![]() |
1 500 V DC
Cluster / container main
|
630 – 1 800 A
|
250 kA
Extremely high · TC 4 ms
|
Cluster-level busbar, container main disconnect, high-capacity PCS. |
|
ESS3
aR · IEC 60269-4 / UL 248-13 · 1 500 V
|
![]() |
1 500 V DC
Rack / cluster level
|
100 – 630 A
|
250 kA
Extremely high · TC 4 ms
|
Module and cluster protection, rack-level isolation, mid-size containers. |
|
PV15M
gPV · 1 500 V DC · UL 248-19 · also PV string protection
|
![]() |
1 500 V DC
PCS DC side / PV string
|
63 – 630 A
|
50 – 150 kA
High · TC 1–3 ms
|
PCS DC side and PV string protection, 1 500 V system, TUV / UL. |
|
ESS2X
aR · 1 500 V · microswitch indicator option (-NI = none)
ESS2X-100ESS2X-250ESS2X-400ESS2X-450
|
![]() |
1 500 V DC
Module / rack level
|
100 – 450 A
|
250 kA
Extremely high · full range
|
Module and rack protection; microswitch version for remote blown-fuse signalling. |
|
ESS2
aR · UL 248-13 · CE / CCC · flush or US-style ends
|
![]() |
1 500 V DC
Module level
|
100 – 450 A
|
250 kA
Extremely high · TC ≤ 4 ms
|
Module-level protection, compact cabinets, four terminal-style variants. |
|
EHF
aR · 1 000 V DC · 150 kA AC rating as well
EHF-160AEHF-250AEHF-400AEHF-630A
|
![]() |
1 000 V DC
Also 150 kA @ AC
|
160 – 630 A
|
20 kA DC
Moderate · 150 kA AC
|
1 000 V storage strings, PCS, UPS, industrial DC distribution. |
|
BSF (NH)
gBat · NH size 1/2/3 · 1 000 V battery storage links
BSF-63GBSF-200GBSF-400G
|
![]() |
1 000 V DC
gBat operating class
|
63 – 400 A
|
100 kA
Very high · TC 4.5 ms
|
Battery array combiners, disconnects, NH base mounting, dual indicator. |
|
H25ESS
aR · UL 248-13 · PCB or bolt-in mounting
|
![]() |
250 V DC
Low-voltage strings
|
32 – 180 A
|
20 kA
Moderate · DC
|
Low-voltage storage, PCB-mounted protection, 48 – 250 V DC systems. |
Notes|Breaking capacity = maximum interrupting rating at rated voltage, DC unless noted; AC and DC ratings differ and are shown separately where applicable.
|Voltage and current ranges are the envelope across the listed series — individual catalogue numbers cover a narrower band.
|Ratings per the corresponding Bussmann datasheet and UL / IEC standard shown in each row; always confirm against the dedicated datasheet before specifying.
|Product images extracted from the matching Bussmann datasheets.