◎ Global Shippingϟ Fast RFQ Response◇ Multi-Brand Supply
Request a Quote
Eaton Bussmann

Bussmann 2BCLS-2R 70A 2.4kV AC R-Rated current-limiting motor fuse

Part Number: 2BCLS-2R

● LT: 12-16w

Eaton Bussmann 2BCLS-2R, 70A, 2.4kV AC; interrupting rating 50kA Sym / 80kA Asym.

Rated Current70A
Rated Voltage2.4kV AC
Breaking Capacity50kA Sym / 80kA Asym
PackageR-Rated Bolt-In

Eaton Bussmann 2BCLS-2R is a R-Rated / Class R R-Rated current-limiting motor fuse rated 70A at 2.4kV AC. Interrupting rating: 50kA Sym / 80kA Asym. Standards: ANSI C37.46|IEEE C37.41. R designation: 2R. Bolt-in construction.

Quick answer, specifications & FAQ
Direct answer

Eaton Bussmann R-Rated Medium Voltage Motor Fuse 2BCLS-2R is rated 70A, 2.4kV AC, R-Rated Bolt-In. Breaking capacity 50kA Sym / 80kA Asym, operating temperature -40°C to +125°C, certifications IEEE Std. C37.41. Listed applications: Motor protection. Standards: ANSI C37.46, ANSI/IEEE R-Rated, IEEE C37.41. Eaton Bussmann 2BCLS-2R, 70A, 2.4kV AC; interrupting rating 50kA Sym / 80kA Asym.

Last updated 23 days ago

Key specifications

  • Part number: 2BCLS-2R
  • Brand: Eaton Bussmann
  • Rated current: 70A
  • Rated voltage: 2.4kV AC
  • Breaking capacity: 50kA Sym / 80kA Asym
  • Package size: R-Rated Bolt-In
  • Dimensions: See Eaton Technical Data 6001
  • Terminal type: Bolt-In
  • Operating temperature: -40°C to +125°C
  • Certifications: IEEE Std. C37.41
  • Standards: ANSI C37.46, ANSI/IEEE R-Rated, IEEE C37.41
  • Typical lead time: 12-16 weeks

Frequently asked questions

What are the current and voltage ratings of 2BCLS-2R?

2BCLS-2R is rated 70A at 2.4kV AC.

What is the breaking capacity of 2BCLS-2R?

2BCLS-2R has a breaking capacity of 50kA Sym / 80kA Asym. Confirm this covers the available fault current at the installation point.

What package size does 2BCLS-2R use?

2BCLS-2R uses R-Rated Bolt-In package size.

Which standards and approvals apply to 2BCLS-2R?

2BCLS-2R is listed under ANSI C37.46, ANSI/IEEE R-Rated, IEEE C37.41 / IEEE Std. C37.41.

What is 2BCLS-2R used for?

2BCLS-2R is listed for Motor protection applications. Verify suitability for your circuit before ordering.

What are the ordering terms for 2BCLS-2R?

2BCLS-2R: typical lead time 12-16 weeks, minimum order 10 pcs. Submit a quote request for a firm quotation.

Data sources

Part number
2BCLS-2R
Brand
Eaton Bussmann
Last updated
2026-10-10
Canonical URL
https://fusestock.com/products/eaton-bussmann-2bcls-2r/

Technical Specifications

Part Number
2BCLS-2R
Manufacturer Part Number
2BCLS-2R
Series
2BCLS
Fuse Type
R-Rated Medium Voltage Motor Fuse
Current Rating
70A
Voltage Rating
2.4kV AC
AC / DC
AC
Breaking Capacity
50kA Sym / 80kA Asym
Operating Temperature
-40°C to +125°C
Package / Dimensions
R-Rated Bolt-In
Mounting
Bolt Mount
Application
Motor protection
Standard
ANSI C37.46 · ANSI/IEEE R-Rated · IEEE C37.41
Terminal Type
Bolt-In
Utilization Class
Class R · R-Rated
Approvals
IEEE Std. C37.41
Certifications
IEEE Std. C37.41
Reference Lead Time
12-16 weeks
Minimum Order
10 pcs
Sample Status
Contact for Availability
R designation
2R
Rated current
70A
Nominal voltage
2.4kV AC
Interrupting rating
50kA symmetrical / 80kA asymmetrical