◎ Global Shippingϟ Fast RFQ Response◇ Multi-Brand Supply
Request a Quote
Eaton Bussmann

Eaton Bussmann KDY 600V AC Cable Limiter

Part Number: KDY

● Check availability

KDY: 600V AC; Cable Limiter; Current-Limiting; 200kA AC.

Rated Voltage600V AC
Breaking Capacity200kA AC

Eaton Bussmann KDY is a cable limiter at 600V AC. Interrupting rating: 200kA AC. Typical applications: Low-voltage distribution cables, Service entrance cable short-circuit protection. Conductor size: 4 AWG. Catalog terminal style varies by model. Source: Bussmann Full Line Catalog 1007 (2018), page 2-3.

Quick answer, specifications & FAQ
Direct answer

Eaton Bussmann Cable Limiter KDY is rated 600V AC, Current-Limiting. Breaking capacity 200kA AC. Listed applications: Low-voltage distribution cables, Service entrance cable short-circuit protection. KDY: 600V AC; Cable Limiter; Current-Limiting; 200kA AC.

Last updated 44 days ago

Key specifications

  • Part number: KDY
  • Brand: Eaton Bussmann
  • Rated voltage: 600V AC
  • Breaking capacity: 200kA AC
  • Fuse speed: Current-Limiting
  • Terminal type: Bolt / Tubular by model
  • Typical lead time: 12-16 weeks
  • Conductor size: 4 AWG. Catalog terminal style varies by model.; Source: Bussmann Full Line Catalog 1007 (2018), page 2-3.

Frequently asked questions

What is the breaking capacity of KDY?

KDY has a breaking capacity of 200kA AC. Confirm this covers the available fault current at the installation point.

What is KDY used for?

KDY is listed for Low-voltage distribution cables, Service entrance cable short-circuit protection applications. Verify suitability for your circuit before ordering.

What are the ordering terms for KDY?

KDY: typical lead time 12-16 weeks. Submit a quote request for a firm quotation.

Data sources

Part number
KDY
Brand
Eaton Bussmann
Last updated
2026-09-19
Canonical URL
https://fusestock.com/products/eaton-bussmann-kdy-600v-ac-cable-limiter/

Technical Specifications

Part Number
KDY
Manufacturer Part Number
KDY
Series
K Series (600V Cable Limiter)
Fuse Type
Cable Limiter
Voltage Rating
600V AC
AC / DC
AC
Breaking Capacity
200kA AC
Mounting
Cable Mount
Application
Low-voltage distribution cables · Service entrance cable short-circuit protection
Terminal Type
Bolt / Tubular by model
Fuse Speed
Current-Limiting
Utilization Class
Cable Limiter
Reference Lead Time
12-16 weeks
Conductor size
4 AWG. Catalog terminal style varies by model.; Source: Bussmann Full Line Catalog 1007 (2018), page 2-3.