Part 30TS-090L is a HOLLY FUSE 30TS-series slow-blow microfuse with ratings of 9A, 125V AC. Interrupting capacity: 50A at 125V AC. Technical data checked against manufacturer catalogue p25.
Specifications
- Series: 30TS
- Rated current: 9A
- Rated voltage: 125V AC
- Fuse characteristic: Slow-Blow
- Fuse construction: Microfuse
- Standards: UL 248-1, UL 248-14
- Interrupting capacity: 50A at 125V AC
- Manufacturer-listed approval authorities: CCC, VDE, UL/cUL, UR/cUR, CSA and PSE are listed by the manufacturer
- exact approvals vary by rating and voltage.
- Operating temperature: -55°C to +125°C
- Source: Hollyland Current Fuse catalogue, printed page 25
Technical Specifications
- Part Number
- 30TS-090L
- Manufacturer Part Number
- 30TS-090L
- Series
- 30TS
- Fuse Type
- Microfuse
- Current Rating
- 9A
- Voltage Rating
- 125V AC
- AC / DC
- AC
- Breaking Capacity
- 50A at 125V AC
- I²t
- 78.7 A²s
- Pre-arcing I²t
- 78.7
- Total I²t
- 78.7
- Operating Temperature
- -55°C to +125°C
- Package / Dimensions
- 3.6×10mm
- Mounting
- Cartridge / Clip
- Application
- Electronic Circuit Protection
- Standard
- UL 248-1 · UL 248-14
- Terminal Type
- Radial Lead
- Fuse Speed
- Time Delay
- Reference Lead Time
- 2–4 weeks
- Rated current
- 9A
- Rated voltage
- 125V AC
- Fuse characteristic
- Slow-Blow
- Fuse construction
- Microfuse
- Standards
- UL 248-1, UL 248-14
- Interrupting capacity
- 50A at 125V AC
- Manufacturer-listed approval authorities
- CCC, VDE, UL/cUL, UR/cUR, CSA and PSE are listed by the manufacturer; exact approvals vary by rating and voltage.
- Operating temperature
- -55°C to +125°C
- Source
- Hollyland Current Fuse catalogue, printed page 25